Skip to main content

URSim Driver

This driver allows the communication between Simumatik and URSim to connect to exchange I/O variables and axis values in degrees.

Parameters​

Aside from the common parameters described in the communication_driver docs, this driver includes:

ParameterDefault ValueDescription
host127.0.0.1IP address of the UR robot.
port30004Port number used by the UR robot.
frequency125Refreshing time value.

Setup data​

The setup data will give values to the parameters required and will specify the I/O variables info.

{
"parameters": {
"host": "localhost",
"port": 30004,
"frequency": 125
},
"variables": {
"inputs": {
"datatype": "byte",
"size": 1,
"operation": "write"
},
"outputs": {
"datatype": "byte",
"size": 2,
"operation": "read"
}
}
}
note

The setup_params in the generic PLC components for ur_driver will need the following format:

{ "host": "localhost", "port": 30004, "frequency": 125 }